KEW 3025A

  • Short-Circuit Current up to 1.5mA
  • Diagnosis Function of PI and DAR
  • Newly-designed alligator clip
  • It comes with a tough hard case
  • Filter function reduces noise interference for obtaining stable measurement
  • Large display with Bar Graph indication and backlight
  • Live voltage warning
  • Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
  • (Photo: 3125A)

CEAutoDischarge

  • DCACV
  • Backlight
  • AutoPowerOff
  • 250V
  • 500V
  • 1000V
  • 2500V

Insulation resistance

Rated voltage 250V 500V 1000V 2500V
Accuracy 0.0 – 100.0MΩ 0.0 – 99.9MΩ
80 – 1000M Ω
0.0 – 99.9MΩ
80 – 999MΩ
0.80 – 2.00G  Ω
 0.0 – 99.9MΩ
80 – 999MΩ
0.80 – 9.99GΩ
8.0 – 100.0GΩ
±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt
Short circuit current 1.5mA
Output voltage
Accuracy ±10% -10 – +20% 0 – +20%
Monitor ±10%rdg±20V

Voltage measurement

Measuring range AC: 30 – 600V (50/60Hz), DC: ±30 – ±600V
Accuracy ±2%rdg±3dgt

General

Applicable standards IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2,
IEC 61010-031, IEC 61326-1, 2-2
Power source DC12V : LR14/R14 × 8pcs
Dimensions 177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Hard case)
Weight 3025A: 1.7kg approx. (including batteries)
4kg approx. (including accessories)
Included Accessories 7165A (Line probe: 3m), 7264 (Earth cord: 3m), 7265 (Guard cord: 3m),
8019 (Hook type prod), 9180 (3025A Hard case), 9181 (3125A Hard case),
LR14 (Alkaline battery size C) × 8, Instruction manual
Optional Accessories 7168A (Line probe with alligator clip: 3m),
7253 (Longer line probe with alligator clip: 15m),
8302 (Adaptor for recorder)