KEW 6024PV

  • Correct measuring for Insulation resistance even if the panel is under generating power
  • Waterproof design: Can measure under the bad weather condition
  • Memory function up to 1000 data
  • Luminescence button and Backlight

CE

  • Backlight
  • USB
  • AutoPowerOff
Insulation resistancePV insulationInsulation
Test voltage500V1000V250V500V1000V
Measuring range
(Auto range)
20.00/200.0/2000MΩ20.00/200.0/2000MΩ
Mid-scale value50MΩ
Rated current1.0-1.2mA
0.25MΩ0.5MΩ1MΩ
First effective
measuring range
1.51-200.0MΩ1.51-1000MΩ1.51-100.0MΩ1.51-200.0MΩ1.51-1000MΩ
Accuracy±1.5%rdg±5dgt±1.5%rdg±5dgt
Second effective
measuring range
0.00-1.50MΩ0.00-1.50MΩ1.20-1.50MΩ1.20-1.50MΩ1.20-1.50MΩ
200.1-2000MΩ1001-2000MΩ100.1-2000MΩ200.1-2000MΩ1001-2000MΩ
Accuracy±5.0%rdg±6dgt
Open circuit voltage0 – +20%
Short circuit currentMax 1.5mA
Earth resistance
Measuring range
(Auto range)
20.00/200.0/2000Ω
Accuracy±3.0%rdg±0.1Ω (20Ωrange) ±3.0%rdg±3dgt (200/2000Ωrange)
Voltage measurement
Measuring rangeAC 5-600V (45-65Hz) DC ±5-±1000V
Accuracy±1.0%rdg±4dgt
General
Applicable StandardsIEC 61010-1 CAT Ⅲ 600V, CAT IV 300V Pollution2
IEC 61010-2-030, IEC 61010-031(EMC), IEC 60529(IP54),
IEC 61557-1,-2,-5,-10, IEC 61326-1,2-2, EN50581(RoHS)
Power sourceLR6(AA)(1.5V) x 6
Dimensions /
Weight
84(L) x 184(W) x 133(D)mm / Approx. 900g (including batteries)
Accessories7196A(Test leads with remote control switch),
7244A(Test lead with alligater clip), 8017(Extension prod),
8072(CAT II standard prod),
8212-USB(USB adaptor with “KEW Report (Software)”),
9155(Shoulder strap), 9156(Carrying case), LR6x6, Instruction manual
Optional7243(L-shaped probe), 7245A(Precision measurement cord set),
8016(Hook type prod)

Accessories/ Optional Accessories /Related Products


Other Products

KEW 6516BT

MODEL 6018

KEW 6516

MODEL 6011A

KEW 6010B

uporn redrube fetishtube.cc tube8