KEW 6516BT

  • A lot of Testing Power in the hands of Electrical Installation Professionals!
new Auto Discharge ce att
KEW-CONNECT
DISPLAYColor LCD 3.5 inches dot matrix.
ATTAnti-Trip Technology (with 2 & 3 wire) for no trip LOOP L-PE testing on all RCDs.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).
LOOPHigh test current range of 2Ω with 0.001Ω resolution.
Zs Limit compares the values required by Electrical Installations Standard with measured results.
RCDType AC, A, F, B(General & Selective), EV and Variable RCDs.
Single and Autotest, Ramp test, and Contact voltage.
EARTHEarth resistance test 2 and 3 wires with all accessories included.
INSULATIONResistance test 100, 250, 500 & 1000V with auto discharge voltage.
CONTINUITYContinuity test at 200mA or 15mA with selectable buzzer for fast judgment.
PHASE ROTATIONOn 3-phase lines with a clear indication of the sequence on the display.
VOLTSTRMS Voltage measurements 2-600V, Mains Frequency.
HELPDisplay shows how to connect the instrument according to the function selected.
SPDSurge Protection Device test, for SPD that uses varistor.
PATPortable Appliance Tester function, for Insulation and Protective conductor resistance test
BluetoothCommunication by “KEW CONNECT”
SAFETYIEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,7,10.
More Info
Insulation resistanceSPD(Varistor)
Test
voltage
100V250V500V1000VMax.1000V
Measuring
ranges
2.000/20.00/200.0MΩ
(Auto-ranging)
20.00/200.0/1000MΩ
(Auto-ranging)
20.00/200.0/2000MΩ
(Auto-ranging)
0-1000V
(goes up by 1V)
Accuracy±2%rdg±6dgt
(2.000/20.00MΩ)
±5%rdg±6dgt
(200.0MΩ)
±2%rdg±6dgt
(20.00/200.0MΩ)
±5%rdg±6dgt
(1000MΩ)
±2%rdg±6dgt
(20.00/200.0MΩ)
±5%rdg±6dgt
(2000MΩ)
±5%rdg±5dgt
Rated
current
1.0-1.2mA
@0.1MΩ
1.0-1.2mA
@0.25MΩ
1.0-1.2mA
@0.5MΩ
1.0-1.2mA
@1MΩ
Short circuit current1.5mA max
Loop impedance
FunctionLOOP ATTLOOP HIGH
L-PE/L-N
(3wire)
L-PE(2wire)L-PE
(0.01ΩRes)
L-PE
(0.001ΩRes)
High test
current(25A)
L-N/L-L
Rated
voltage
100-260V
(50/60Hz)
48-260V
(50/60Hz)
48-260V
(50/60Hz)
100-260V
(50/60Hz)
48-500V
(50/60Hz)
Impedance
range
20.00/200.0/2000Ω
 (Auto-ranging)
20.00/200.0/
2000Ω  
(Auto-ranging)
2.000Ω20.00Ω
Accuracy±3%rdg±6dgt ±3%rdg±10dgt±3%rdg±4dgt±3%rdg±25mΩ±3%rdg±4dgt
Nominal   
test
current at
0Ω external
loop:
Magnitude/
Duration at 230V 
L-N:6A/60ms
N-PE:10mA
L-PE:15mA20Ω:
  6A/20ms
200Ω:
  0.5A/20ms
2000Ω:
  15mA/500ms
25A/20ms6A/20ms
PSC/PFC 
Range 

2000A/20kA 
(L-N(PSC)/
L-PE(PFC))

2000A/20kA 
(PFC)
2000A/20kA 
(PFC)
2000A/50kA 
(PFC)
2000A/20kA
(PSC)
AccuracyPSC/PFC accuracy is derived from measured loop impedance specification
and measured voltage specification
RCD
Rated voltage100-260V(50/60Hz)
Functionx1/2, x1,x5,Ramp,Auto,Uc
6/10/30/100/300/500/1000mA/variable
RCD typeAC(G/S)A(G/S)F(G/S)B(G/S)EV
Trip
current
setting
x1/2,
x1,Uc
10/30/100/300/
500/1000mA(G)
10/30/100/
300/500(S)
10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300mA
6mA(x1 only)
x510/30/100mA10/30/100mA10/30/100mA10/30mA
Ramp10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300mA
6mA
Accuracy
Trip
current
x1/2-8% – -2%-10% – 0%-10% – 0%-10% – 0%
x1+2% – +8%0% – +10%0% – +10%0% – +10%0% – +10%
x5+2% – +8%0% – +10%0% – +10%0% – +10%
Ramp-4% – +4%-10% – +10%-10% – +10%-10% – +10%-10% – +10%
Trip
time
x1/22000ms(G/S):±1%rdg±2ms
x1550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms10.5s:±1%±2㎳
x5410ms(G/S):±1%rdg±2ms
Continuity
Range 20.00/200.0/2000Ω (Auto-ranging)
Open circuit voltage(DC)7-14V
Measuring current 200mA>200mA or more(2Ω or less)
15mA15mA±3mA(short-circuit)
Accuracy ±2%rdg±8dgt
Volts
Range 300.0/600V(Auto-ranging)
Measuring rangesVolts2-600V
Frequency45-65Hz
AccuracyVolts±2%rdg±4dgt
Frequency±0.5%rdg±2dgt
Phase Rotation
Rated voltage48-600V(50/60Hz)
RemarksRemarks Correct phase sequence: are displayed “1.2.3” and mark
Reversed phase sequence: are displayed “3.2.1” and mark
Earth
Range 20.00/200.0/2000Ω(Auto-ranging)
Accuracy±2%rdg±0.08Ω(20.00Ω)
±2%rdg±3dgt(200.0/2000Ω)
Applicable standardsIEC 61010-1 CAT IV 300V ,CAT III 600 V Pollution degree 2
IEC 61010-2-034
IEC 61557-1,2,3,4,5,6,7,10
IEC 60529(IP40)
IEC 61326(EMC)
Power sourceLR6 (AA) (1.5V) ×8
Communication interfaceUSB, Bluetooth®5.0,Android™5.0 or more, iOS 10.0 or more ※1
Dimensions / Weight136(L) × 235(W) × 114(D) mm / Approx. 1300g (including batteries)
Included AccessoriesMain test lead※2
7281(Test leads with remote control switch)
7246(Distribution board test lead)
7228A(Earth resistance test leads)
8041(Auxiliary earth spikes[2 spikes/1 set])
9084(Soft case)
9142(Carrying case)
9151(Shoulder strap)
9199(Shoulder pad)
LR6(AA) × 8, Instruction manual, Calibration certificate
Optional Accessories8212-USB(USB adaptor with “KEW Report(Software)”)
8259(Adapter for measurement terminal)
7272(Precision measurement Cord set)
8017A(Extension prod long)

※1 Bluetooth is a trademark or registered trademark of Bluetooth SIG. Inc. Android is a trademark or registered trademark of Google Inc. iOS is a trademark or registered trademark of Cisco Technology, Inc. in the United States and other countries.
※2 7187A: British plug, 7218A:(EU)European SHUKO plug, 7221A: (SA)South African plug, 7222A: (AU)Australian plug


Various features

Large LCD & HELP function
  • All the test data is shown in one large colored screen.
  • HELP function will show how to connect the instrument according to the function selected


Operation in 3 simple steps & Hands free testing
  1. Set the rotary dial to your testing range.
  2. Connect the instrument to the installation under test.
  3. Press the test button.(By remote probe or using the Lockdown function of the test button.)

Anti-Trip Technology (with 2 & 3 wire)

For no trip LOOP L-PE testing on all RCDs.
With 3 wire (L, N, PE), to get the best accuracy readings.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).

Loop Impedance 0.001 resolution

High test current range of 2Ω with 0.001Ω resolution.

Zs/Ra Limit

Zs Limit compares the values required by Electrical Installations Standard with measured results.

The verification of safety requirement on an electrical installation is simplified by using Zs/Ra Limit function. This function will automatically check if the measured loop impedance for TN (or earth loop for TT) is low enough to trip (disconnect) the MCB / Fuse / RCD giving the result of PASS or FAIL on the display.

SPD test

SPD (Surge Protection Device) which contains varistor can be tested measuring the tripping voltage without damage it.

PAT test

PAT test (PAT = Portable Appliance Tester) It is possible to check the insulation resistance and earth bond continuity of portable appliances for class I and II.

Connectivity
Bluetooth

Use the application KEW Smart* to improve work efficiency.

KEW 6516BT can trancfer the test data toa Tablet or Smartphone via Bluetooth.
Such test data can be saved, shared and sent by email.




KEW Smart*

Please search “KEW Smart”
Communication charge may be incurred separately to download application.

Application for Android
Free Android software “KEW Power” 
is available on “Google Play Store”
Supporting Android ver.5.0


Application for iOS
Free iOS software “KEW Power” 
is available on “APP Store”
Supporting iOS 10.0


USB

Use the PC application KEw Report to improve work efficiency.

KEW 6516BT can download the test data by connecting the USB adaptor (Model 8212-USB for option) and then print complete Test Reports by a PC.




Other Products

KEW 6024PV

MODEL 6018

KEW 6516

MODEL 6011A

KEW 6010B